High Performance Programmable Temp. and Humidity Test Chamber
Why KOMEG?
1. Specializing in environmental test chamber for 32years
2. Valued customers: HUAWEI, TCL, EMERSON, EPSON, OMRON, GREE, SGS,FOXCONN,etc.
3. Imported Tecumseh or Danfoss compressor
4. LED Touch Screen Controller
5. One year free parts warranty
6. Customized sizes and configurations available
Enclosure structure characteristics
1.The box body is pro-forming by cnc machine, modelling beautiful generous, and with no reaction handle, easy to operate.
2.Enclosure bladder made of imported advanced stainless steel (SUS304) mirror plate, outside the box body is coated with A3 steel, increase the appearance quality and cleanliness.
3.The large observation window attached lamp too keep brighting inside cabinet, and use of fever embedded toughened glass,clear observate the condition in the cabinet at any time.
4.The left side of the cabinet with a diameter of 50 mm hole, used for external test power supply cord or signal lines.
controller
1.Temperature control adopts imported touch button type instrument, simple operation setting.(Japan RKC waalwijk)
2.After input data and test conditions, controller with locking function, avoid human touch and temperature change.
3.With the function of automatic calculus of P.I.D,can be corrected the temperature change conditions mmediately, make more accurate and stable temperature control.
4.Optional printer.
Frozen and the wind road system
1.Chiller adopting French "Taikang" enclosed totally compressor.
2.The refrigeration system use unit or binary type low temperature circuit system .
3.Adopt more wing type blower air supply cycle, to avoid any dead space, can make the uniform temperature distribute in the test area.
4.The wind circle with outlet air and return air design, the wind velocity are accord with test standard, and can make the door instantaneous temperature stabilizing time fast.
5.Completely independent of heating, cooling, system can improve the efficiency and reduce test cost, increase longevity, reduce the failure rate.
Meet The Standards
GB-2423.1-89(IEC68-2-1)Test A:Low Temperature Test
GB-2423.2-89(IEC68-2-2)Test B:High Temperature Test
GJB360.8-87(MIL-STD.202F) High Temperature Life Test
GBJl50.3(MIL-STD-810D) High Temperature Test
GJBl50.4(MIL-STD-810D) Low Temperature Test
GB2423.3-93(IEC68-2-3)Test Ca:Constant Heat Test
GB2423.4-93(IEC68-2-30)Test Db:Damp Heat Alternative Test
GJBl50.9-93(MIL-STD-810D) Damp Heat Test
Operating technical parameter
Environmental Temperature and Humidity Chamber |
|
Secifications ( at +20ºC room temp. Or+25ºC water temp with empty load) |
Model |
KMH-R series |
KMH-L series |
KMH-S series |
150R |
225R |
408R |
800R |
1000R |
150L |
225L |
408L |
800L |
1000L |
225S |
408S |
800S |
1000S |
Temp. range |
-20ºC~150ºC |
-40 ºC~+150ºC |
-70ºC~+150ºC |
Interior sizel |
W(mm) |
600 |
700 |
700 |
1000 |
1000 |
600 |
700 |
700 |
1000 |
1000 |
700 |
700 |
1000 |
1000 |
H(mm) |
600 |
700 |
750 |
1000 |
1000 |
600 |
700 |
750 |
1000 |
1000 |
700 |
750 |
1000 |
1000 |
D(mm) |
460 |
480 |
800 |
800 |
1000 |
460 |
480 |
800 |
800 |
1000 |
480 |
800 |
800 |
1000 |
Exterior size |
W(mm) |
880 |
980 |
980 |
1280 |
1280 |
880 |
980 |
980 |
1280 |
1280 |
980 |
980 |
1280 |
1280 |
H(mm) |
1730 |
1890 |
1940 |
2160 |
2160 |
1730 |
1890 |
1940 |
2160 |
2160 |
1890 |
1940 |
2160 |
2160 |
D(mm) |
1400 |
1460 |
1740 |
1750 |
1950 |
1400 |
1460 |
1740 |
1750 |
1950 |
1460 |
1740 |
1750 |
1950 |
Power(KW) |
5.8 |
6 |
7.5 |
12.8 |
12.8 |
7.5 |
7.5 |
8.5 |
14.5 |
14.5 |
9.5 |
10.6 |
18.5 |
18.5 |
Weight(KG) |
240 |
280 |
400 |
500 |
580 |
250 |
300 |
420 |
530 |
600 |
330 |
450 |
550 |
650 |
Humidity uniformity |
±3.0%R.H |
±5.0%R.H |
±3.0%R.H |
±5.0%R.H |
±3.0%R.H |
±5.0%R.H |
Heat up time |
-20ºC~+100ºC,within 35 min |
-40ºC~+100ºC, within 45 min |
-70ºC~+100ºC,within 60 min |
Pull down time |
+20ºC~-20ºC, within 45 min |
+20ºC~-40ºC , within 60 min |
+20ºC~-70ºC,within 80 min |
Standard accessories |
Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m |
Safety device (standard) |
No fuse breaker, over pressure\over heat and over current protection for compressor,
Over temp. protect, over load protect of blower, dry heat protection |
Control System |
Balanced Temperature & Humidity Control System |
Refrigeration system |
Air Cooled (Water Cooled Type is option) |
Hermetic compressor,Single stage refrigeration system, CFC-Free refrigerant(HFC-507/HFC-23) |
Hermetic compressor, Cascade Refrigeration , CFC free refrigerant (HFC-507/HFC-23) |
Controller |
Panel:7-inch LCD Touch panel, Chinese or English display selectable |
Operation model :Program or fix point running |
Memory capacity :120programs,1200steps, |
All repeat 999 cycles, part repeat 99 cycles |
Humidity Range |
20~98%R.H |
Temp. constancy |
±0.5ºC |
Humidity constancy |
±2.5%R.H |
Temp. uniformity |
±2.0ºC |
Interior material |
Stainless Steel Plate(SUS 304) |
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam and Glass Fiber Wool |
Ambient Temp. |
+5ºC~+35ºC |
Wiring method |
|
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |
Note: 1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available |
After-sale service
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.