Athlete Training Walk-in Environmental Test Chamber/ Climatic Chamber
Application:
Walk-in chambers can be used for testing and controlled storage as well as a multifunctional laboratory environment for conducting test procedures in the telecommunications, defense, aerospace, pharmaceutical, automotive, and electronics industries. Chamber sizes can always be customized to your testing needs.
Environments:
Steady-state temperature and temperature/ humidity tests
Moderate temp./humidity cycling test (< 9°F/5°C/min.)
Moderate temperature heat aging (<176°F/80°C)
Chamber Features:
Economical cost
Ease of move in and install
Wide range of size and performance
Engineered cooling modules
Controller: LED Touch Screen Programmable Controller
Refrigeration system: Water-cooled
Performance:
Temperature range for single stage refrigeration: -4°F/-20°C to 176°F/80°C
Temperature range for cascade refrigeration: -100°F/-73°C to 176°F/80°C.
Humidity Range: 10% to 95 RH within the bounds of a 158°F/70°C max. dry-bulb and a 40°F/4°C min. dewpoint.
Technical parameter
SPECIFICATIONS |
Note: We reserve the right to change specifications without prior notice |
Model |
KMHW- |
4 |
6 |
8 |
13 |
17 |
21 |
Volume(m³) |
9 |
12.9 |
16.8 |
16.8 |
35.2 |
13.3 |
Interior Dimensions |
W(mm) |
2100 |
3000 |
3900 |
3000 |
3900 |
4800 |
H(mm) |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
D(mm) |
2050 |
2050 |
2050 |
4300 |
4300 |
4300 |
Exterior Dimensions |
W(mm) |
3250 |
4160 |
5050 |
5050 |
5050 |
5950 |
H(mm) |
2350 |
2350 |
2350 |
2350 |
2350 |
2350 |
D(mm) |
2250 |
2250 |
2250 |
2250 |
4500 |
4500 |
Safety Devices(standard) |
No fuse breaker, over pressure\over heat and over current protection for compressor,over-temperature protection, overload protection for the blower, dry heat protection |
Standard accessories |
Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator |
Control System |
Balanced Temperature & Humidity Control System |
Refrigeration system |
Water Cooled |
Semi-hermetic compressor, single-stage or cascade refrigeration system, |
CFC free refrigerant(HFC-507 and HFC-23) |
Controller |
Panel |
7-inch LCD Touch panel, Chinese or English display selectable |
Operation model |
Program or fixpoint running |
Memory capacity |
120 programs,1200steps, all repeat 999 cycles, part repeat 99 cycles |
Accuracy |
Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit |
Input |
Temp.:pt-100, Humidity:pt-100 or ~5V DCV |
Comm.port |
RS-232 or RS-485 (Software is an option) |
Temp. range |
Maximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40ºC,-30ºC,-20ºC,-10ºC,0ºC |
Humidity Range |
10%,20%,30%~95% |
Temp. constancy |
±0.5ºC |
Humidity constancy |
±2.5%R.H |
Temp. uniformity |
±2.0ºC |
Humidity uniformity |
±5.0%R.H |
Ambient Temp. |
+5ºC~+35ºC |
Wiring method |
AC 380±10%50Hz,3 phase 4 wires +Ground Wires |
Heat uptime |
+20ºC~+80ºC, Within 60 min |
Pull downtime |
+20ºC~-55ºC\ -40ºC\-20ºC\-10ºC ,Within 120 or 90 or 60 min |
Interior material |
Stainless Steel Plate(SUS 304) |
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
Insulation material |
Rigid polyurethane foam |
Door size (mm) |
Single wing:W800*H1800;Double wing:W1600*H1800; |
Note:
1. We reserve the right to change specifications without prior notice
2.Customized sizes and configurations available |
![Athlete Training Walk-in Environmental Test Chamber/ Climatic Chamber](//www.micstatic.com/athena/img/transparent.png)
Packaging
Each set protected with resin fiber and PP film, then put into a Strong wooden case with operation manual and video inside.
After-sale service
If you face any problems in the future during the testing process we promise we will give you a reply within 48 hours and the solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by the customer.