Two Zone Programmable Thermal Shock Test Equipment TST-64A
Application
The product is suitable for electronic elements' safety test, and provides a reliability test, at the same time, this equipment test, can improve the reliability of products and product quality control.
Enclosure structure characteristics
1. Vertical, two-zone chamber has hot and cold zones that can be controlled independently.
A horizontal, three-zone thermal shock chamber utilizes controlled areas for hot, ambient, and cold temperatures.
2. Double-duty thermal shock chambers from KOMEG are designed with hot zones above and below the cold zone and a two-compartment product carrier that simultaneously moves products between the hot and cold zones
Controller System
1. Low-temperature and high-temperature zone conversion time less than or equal to 15 seconds.
2. The temperature recovery time is less than or equal to 5 minutes.
Meet The Standards
GB/T2423.1.2
GB10592-89
GJB150
Product Technology
A, The controller system features:
Centralized controller, recorder, computer triad controller;
1. Provide USB port, R485 interface, and USB download;
2. Large capacity may save 13450 segments, with super long running of 530 hours for each segment.
3. Program loop can be 32000 times, tiny loop 32000 times;
4. Large built-in storage, which can store 90-day calendar data, and historical curves (when the sample is 1 min)
5. Support English, Chinese, and so on.
Refrigeration system characteristics
1. Import compressor, reduce the operating noise, better performance;
2. The unit module standardization. Set up the bend language manual, and ensure that it makes unity. The cooling line adopts an advanced bend language process, ensuring refrigeration is accurate, and uniform;
3. The operation of the refrigeration system adopts intelligent control, power consumption is small, all refrigeration parts assume internationally famous brands, and quality is assured for long-term stable operation.
4. Modular making, ease to installation, repair, and maintenance; Air-cooled condenser of refrigeration unit add the filter net, ensure the regular operation;
5. Intelligent cooling capacity adjustment, good control effect. Wide range of load.
Technical Parameter
3 Zone Thermal Shock Test Chamber |
Specifications |
Note:1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available |
Model |
KTS-A Series |
72A |
100A |
150A |
200A |
252A |
300A |
480A |
Interior size |
W(mm) |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
H(mm) |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
D(mm) |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
Exterior size |
W(mm) |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
H(mm) |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
D(mm) |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
Low Temp. Chamber |
-55ºC~-10ºC |
Pre-heat time |
+20ºC~-55ºC ,Within 60 min |
Test. chamber |
-40ºC~+150ºC |
High Temp. Chamber |
+60ºC~+200ºC |
Pre-heat time |
+60ºC~+200ºC ,Within 20 min |
Recovery time |
High-Temp Exposure 30 min |
Low-Temp Exposure 30 min |
Recovery time within 5 min |
Safety device |
No fuse breaker, over pressure\over heat and over current protection for compressor, over temperature protection, overload protection for the blower, dry heat protection |
Standard accessory |
Cable port(portΦ50mm)*1, shelves*2 |
Interior material |
Stainless steel plate(SUS 304) |
Exterior material |
Baked painting steel or stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam+glass fiber wool |
Refrigeration system |
Water Cooled |
Semi-hermetic compressor, cascade refrigeration system, CFC-free refrigerant(HFC-507 and HFC-23) |
Controller |
Panel:7-inch LCD Touch panel, Chinese or English display selectable |
Operation model: Program or fix point running |
Memory capacity:120programs, 1200 steps, all repeat 999 cycles, part repeat 99 cycles. |
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit |
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV |
Ambient Temp. |
+5ºC~+35ºC |
Power |
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |
3 Zone Thermal Shock Test Chamber |
Specifications |
Note:1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available |
Model |
KTS-B Series |
72B |
100B |
150B |
200B |
252B |
300B |
480B |
Interior size |
W(mm) |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
H(mm) |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
D(mm) |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
Exterior size |
W(mm) |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
H(mm) |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
D(mm) |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
Low Temp. Chamber |
-70ºC~-10ºC |
Pre-heat time |
+20ºC~-70ºC ,Within 60 min |
Test. chamber |
-55ºC~+150ºC |
High Temp. Chamber |
+60ºC~+200ºC |
Pre-heat time |
+60ºC~+200ºC ,Within 20 min |
Recovery time |
High-Temp Exposure 30 min |
Low-Temp Exposure 30 min |
Recovery time within 5 min |
Safety device |
No fuse breaker, over pressure\over heat and over current protection for compressor, over temperature protection, overload protection for the blower, dry heat protection |
Standard accessory |
Cable port(portΦ50mm)*1, shelves*2 |
Interior material |
Stainless steel plate(SUS 304) |
Exterior material |
Baked painting steel or stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam+glass fiber wool |
Refrigeration system |
Water Cooled |
Semi-hermetic compressor, cascade refrigeration system, CFC-free refrigerant(HFC-507 and HFC-23) |
Controller |
Panel:7-inch LCD Touch panel, Chinese or English display selectable |
Operation model: Program or fix point running |
Memory capacity:120programs, 1200 steps, all repeat 999 cycles, part repeat 99 cycles. |
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit |
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV |
Ambient Temp. |
+5ºC~+35ºC |
Power |
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |
3 Zone Thermal Shock Test Chamber |
Specifications |
Note:1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available |
Model |
KTS-D Series |
72D |
100D |
150D |
200D |
252D |
300D |
Interior size |
W(mm) |
450 |
500 |
600 |
670 |
700 |
800 |
H(mm) |
400 |
450 |
500 |
600 |
600 |
600 |
D(mm) |
400 |
450 |
500 |
500 |
600 |
650 |
Exterior size |
W(mm) |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
H(mm) |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
D(mm) |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
Low Temp. Chamber |
-80ºC~-10ºC |
Pre-heat time |
+20ºC~-80ºC ,Within 60 mins |
Test. chamber |
-65ºC~+150ºC |
High Temp. Chamber |
+60ºC~+200ºC |
Pre-heat time |
+60ºC~+200ºC ,Within 20 min |
Recovery time |
High-Temp Exposure 30 min |
Low-Temp Exposure 30 min |
Recovery time within 5 min |
Safety device |
No fuse breaker, over pressure\over heat and over current protection for compressor, over temperature protection, overload protection for the blower, dry heat protection |
Standard accessory |
Cable port(portΦ50mm)*1, shelves*2 |
Interior material |
Stainless steel plate(SUS 304) |
Exterior material |
Baked painting steel or stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam+glass fiber wool |
Refrigeration system |
Water Cooled |
Semi-hermetic compressor, cascade refrigeration system, CFC-free refrigerant(HFC-507 and HFC-23) |
Controller |
Panel:7-inch LCD Touch panel, Chinese or English display selectable |
Operation model: Program or fix point running |
Memory capacity:120programs, 1200 steps, all repeat 999 cycles, part repeat 99 cycles. |
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit |
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV |
Ambient Temp. |
+5ºC~+35ºC |
Power |
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |
After-sale service
If you face any problems in the future during the testing process we promise we will give you a reply within 48 hours and a solution provided within 3 working days. We can offer operation video and English operation muanual. We can provide a video conference. If customers require on-site service, the transport and travel expense shall be borne by the customer.