• Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber
  • Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber
  • Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber
  • Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber
  • Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber
  • Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber

Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber

After-sales Service: 24 Hours on Line Services
Warranty: 12 Months
Certification: CE, ISO, RoHS
Application: School, Hospital, Lab
Type: Environmental Simulation
Temp. Range: -60 Oc~+120 Oc
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
R&D Capabilities
The supplier has 21 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (27)

Basic Info.

Model NO.
KMHW-8
Humidity Range
10%~95%R.H.
Interrior Dimension(W*H*D)
3900*2100*2050mm
Volume(M3)
16.8cbm
Exterior Dimensions(W*H*D)
5050*2350*2250mm
Heat up Time
+20oc~+80oc Within 60mins
Pull Down Time
+20 Oc~-55 Oc Within 120mins
Insulation Material
Glass Wool+Rigid Polyurethane
Refrigeration System
Semi-Hermetic Compressor(Imported)
Transport Package
Strong Plywood Case
Specification
Standard and Customized
Trademark
KOMEG
Origin
Guangdong, China
HS Code
90321000
Production Capacity
1000 Sets Per Yesr

Product Description

Simulation Real Environmental Walk-In Chamber for Temperature Humidity Testing  

Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberSimulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test Chamber

Walk-In Temperature and Climate Test ChambersA KOMEG Walk-In Chamber serves as a test site for large components, assemblies, and finished products. KOMEG manufactures both Panel Walk-In Chambers and Solid Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber

A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation. Usually for electronics temperature aging, like recharger, PCBA, Battery, LCD, scanners, monitors, LED, biological equipment, etc. Outside banding helps prevent leaking and keeps moisture out of the Walk-In Chamber and workspace temperatures steady.

Solid Walk-In Chambers are custom built to accommodate almost any size. They feature welded walls creating an environmental room for applications requiring controlled temperature and humidity testing exceeding 85°C. Typically, for ease of installation, a Solid Walk-In Chamber works best in new construction buildings, areas with extremely large doors, or rooms where outside walls can be easily removed.

 Walk-In Chamber Types

Model Number Temperature Range Humidity Range Temperature Change Recommended Use
Panel Walk-in -60°C to +85°C 20% to 95%RH 1 to 2°C/min Temperature Cycling Temp / Humidity Cycling / Storage Testing
Solid Walk-In -60°C to +150°C 20% to 95%RH 4 to 5°C/min, or faster Temperature Cycling
Temp / Humidity Cycling
Extreme Temp / Humidity Testing
Altitude Testing
Steady State Walk-In -20°C to +50°C 20% to 95%RH N/A Constant Temperature
Constant Temp / Humidity
Storage Testing

Main Technical Parameters

Specification of Walk-In Chambers
Model KMHW-8
Volume(m³) 16.8CBM
Interior Dimensions W3900*H2100*D2050mm
Exterior Dimensions W5050*H2350*D2250mm
Safety Devices(standard) No fuse breaker, over pressure\over heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection
Standard accessories Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator
Control System  Balanced Temperature & Humidity Control System
Refrigeration system Water Cooled
Semi-hermetic compressor, single stage or cascade refrigeration system,
CFC free refrigerant(HFC-507 and HFC-23)
Controller Panel 7-inch LCD Touch panel,Chinese or English display selectable
Operation model Program or fix point running
Memory capacity 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles
Accuracy Temp.:0.1% of F.S±1 digit  Humidity:0.1% of F.S±1 digit
Input Temp.:pt-100, Humidity:pt-100 or ~5V DCV
Comm.port  RS-232 or RS-485 (Softawre is option)
Temp. range Maximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40 ºC,-30ºC,-20 ºC,-10ºC,0ºC
Humidity Range 10%,20%,30%~95%
Temp. constancy ±0.5ºC
Humidity constancy ±2.5%R.H
Temp. uniformity ±2.0ºC
Humidity uniformity ±5.0%R.H
Ambient Temp. +5ºC~+35ºC
Wiring method AC 380±10%50Hz ,3 phase 4 wires +Ground Wires
Heat up time  +20ºC~+80ºC,Within 60 min
Pull down time  +20ºC~-55ºC\-40ºC\-20ºC\-10ºC,Within 120 or 90 or 60  min
Interior material Stainless Steel Plate(SUS 304)
Exterior material Baked Painting Steel Or Stainless steel(SUS304)
Insulation material Rigid polyurethane foam
Door size (mm) Single wing:W800*H1800;Double wing:W1600*H1800;
Note:1. We reserve the right to change specifications without prior notice   2.Customized sizes and configurations available

4. Control method and characteristics:

Precision microcomputer control temperature and humidity system, with PID control the refrigerant flow to make the system's heating / humidification reduction, to achieve low power consumption, energy saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.Flexibility for structure

The panels used in our chamber are 4" (100mm or 150mm) Thick urethane-foam sandwiched between a stainless-steel interior wall and a coated-steel exterior. An assembled box is self-supporting. So that no heavy structural members are required. Different door sizes, flooring upgrades,access ports, and other modifications are possible.

After-sale service

Simulation Real Environmental Walk-in Chamber for Temperature Humidity Testing Test ChamberIf you face any problems in future during testing process we promise we will give you a reply within 24 hours and solution provide within 2 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now