Customization: | Available |
---|---|
After-sales Service: | 24 Hours on Line Services |
Power Supply: | 380V 50Hz |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
LCD Controller Eco-friendly Refrigant Thermal Shock Chamber for PCB Testing
1. 3-Zone Thermal Shock Chambers Working Principle:
The three-zone type thermal shock test chamber. Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. During low temperature test, cold chamber door open, and low-temperature chamber working together with test chamber. When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber.
Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1 second, and the temperature can be quickly stabilized.
During the whole test, test sample is no need to be moved, and without any human intervention.
2. KOMEG Thermal Shock Chambers' Characteristics:
1. Heat preservation material, we use high-intensity PU foam and high density glass fiber cotton, which can assure high precise and better uniformity and avoid unnecessary energy loss. Meanwhile, our design can better assure personnel safety when operating a Walk-in Chamber.
2. Inner wall and housing material:
For small standard models, generally use inner wall of stainless steel #304 1.0mm, housing of stainless steel #304 1.2mm;
For bigger models, or some customized with special needs, we use inner wall of stainless steel #304 1.5 to 3.0mm, housing of stainless steel #304 over 1.5mm;
3. Material quality of inner box is SUS304 # mounted stainless steel imported, and outer box is steel plate and the paint process applies automobile coating technology. Box body is processed shape using Triumph processing machine, its shape is nice and neat.
4. Large-size Full Color LCD touchscreen displayer, simple operation, easy to edit programs. PID with automatic calculation function; self-diagnostic function, show failure message and failure shot solutions step by step.
5. An RS-232 and RS-485 communication interface, matching recorder, strong expandability. We also support remote control by PC via wifi or wire (recommended).
3. Features of Different Cooling Mode for thermal shock chambers:
Since the cold chamber need huge cooling capacity for shocking, the chamber's cooling mode is often designed as air-cooled or water-cooled.
Air-cooled type need installation environment:
The room must be equipped with exhauster and air conditioner to make sure heat dissipation timely.
It's applied to small power products and cool areas.
Water-cooled type need installation conditions:
The customer must prepare water pipe and water tower (located outside) accordingly.
The water must be pure, or it will block the pipes and result in some maintenance trouble with time going.
It's often applied to large system with the features of better heat dissipation, longer service time, low noise but slightly higher price if count the fee of water tower and water pipes.
4. Specification
(1) KTS-A Series
Model |
|
||||||||
72A |
100A |
150A |
200A |
252A |
300A |
480A |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp Chamber |
-55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC |
||||||||
Test Chamber |
-40ºC~+150ºC |
||||||||
High Temp Chamber |
+60ºC~+200ºC ,Within 20 min, Pre-heating time |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
|
||||||||
72B |
100B |
150B |
200B |
252B |
300B |
480B |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp. chamber |
-70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min |
||||||||
Test. Chamber |
-55ºC~+150ºC |
||||||||
High Temp. chamber temperature |
+60ºC~+200ºC,Preheating time: ≤20 min |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
|
||||||||
72D |
100D |
150D |
200D |
252D |
300D |
480D |
|||
Inside size(mm) |
W |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
|
H |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
||
D |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
||
Outside size(mm) |
W |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
|
H |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
||
D |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
||
Test weight |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
||
Low Temp Chamber |
-80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC |
||||||||
Test Chamber |
-65ºC~+150ºC |
||||||||
High Temp Chamber |
+60ºC~+200ºC ,Within 20 min, Pre-heating time |
||||||||
Transition time |
≤15S |
||||||||
Recovery time |
High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample |
||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample |
|||||||||
≤ 5 min |
|||||||||
Ambient Temp. |
+5ºC~+35ºC |
||||||||
Power |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
:
FAQ
1. Do you offer after-sales service? How can I ask for that? And how about the warranty?
Every machine from our factory has a 14-month warranty after shipment. Generally, we offer 12 months for the FREE maintenance, while considering of sea transportation, we can extend 2 months for our customers.
If your machine doesn't work, you can send E-mail to us and we will try our best to find the problem by email or skype video chat if neccesary. After confirmation of the problem, we can send you new spare parts or provide on-site repair.
2. What's the delivery term?
At most of time, we have stock in the factory. If there is no stock, normally, the delivery time is 30-40 working days after deposit receipt. If you are in urgent need, we can consider making a special arrangement for you.
3. Do you accept customization service? Can I have my logo on the machine?
Yes, of course. We can not only offer standard machines, but also customized machines according to your requirements. And we can also put your logo on the machine.
4. How to install and use the product?
We will send you operating instructions, English video by Email. Or you can download on our officail website directly.
Most of our machine is shipped with a whole part, which means it is already installed, all you need to do is to connect the power cable and start to use. And if possible, we can also install your machine at site.