After-sales Service: | 24 Hours on Line Services |
---|---|
Power Supply: | 380V |
Certification: | CE, TUV, ISO |
Warranty: | 1 Year |
Volume(M3): | 12.9 |
System: | Balanced & Humidity Control System |
Customization: |
---|
Suppliers with verified business licenses
Main Technical Parameters ( Air cooled ,at ambient temperature +25ºC no load ) | |
1. Chamber working space : approx 1000L | |
1.1Workspace volume | W 1000× H 1000 × D 1000 mm |
1.2 Exterior size | W 1200×H 2035×D 2015 mm approx |
1.3 Covers Floor space | Approx 2.5m³(Confirmed after the sign order ) |
2. Temperature | |
2.3 Temperature range | -20ºC ~ +60ºC |
2.4 Temp Deviation | <=±2.0ºC |
2.5 Temp Constancy | ±0.5ºC |
2.6 Temp Uniformity | ±2.0ºC |
2.7 Heating rate | -20ºC ~ +60ºC ,average rate 3ºC/min (with load 140kg Battery module) |
2.8 Cooling rate | +60ºC~-20ºC, average rate 3ºC/min (with load 140kg Battery module) |
2.9 Load | 140kg battery module ,70kg/pcs ,2pcs test for one time |
3. Humidity | |
Humidity range | 10~98%R.H(+20ºC~+85ºC,According to the area below) |
Temperature&Humidity range | |
3.1 Humidity Deviation | ±3.0%RH(>75%RH) ±5.0%RH(≤75%RH) |
3.3 Humidity fluctuation | ±2%RH |
3.4 Humidity uniformity | 3.0%RH (no load) |
3.6 Noise | <=70(dB)The noise detection device is measured 1meter away from the door of the chamber |
The temperature and humidity performance test is based on the relevant regulations of IEC60068-3 standard; the sensor is placed at the unit outlet. |