| Customization: | Available |
|---|---|
| Power Supply: | AC380V 25Hz, 3 Phases |
| Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency



| Environmental Temperature and Humidity Chamber | |||||
| Secifications ( at +20°C room temp. Or+25°C water temp with empty load) | |||||
| Model | KMH-S series | ||||
| 225S | 408S | 800S | 1000S | ||
| Interior sizel | W(mm) | 700 | 700 | 1000 | 1000 |
| H(mm) | 700 | 750 | 1000 | 1000 | |
| D(mm) | 480 | 800 | 800 | 1000 | |
| Exterior size | W(mm) | 980 | 980 | 1280 | 1280 |
| H(mm) | 1890 | 1940 | 2160 | 2160 | |
| D(mm) | 1460 | 1740 | 1750 | 1950 | |
| Weight(KG) | 330 | 450 | 550 | 650 | |
| Temp. range | -70 °C ~+150°C | ||||
| Humidity Range | 20 ~ 98&R.H. | ||||
| Temp. constancy | ±0.5ºC | ||||
| Humidity constancy | ±2.5%R.H | ||||
| Humidity uniformity | ±3.0%R.H | ±5.0 % R.H | |||
| Heat up time | -70°C ~ +100°C , within 60 min | ||||
| Pull down time | +20°C ~ -70°C , within 80 min | ||||
| Equipment Power | 9.5KW | 10.6KW | 18.5KW | 18.5KW | |
| Ambient Temp. | 5ºC ~+35ºC | ||||
| Standard accessories | Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m |
||||
| Safety device (standard) | No fuse breaker, over pressure \ over heat and over current protection for compressor, Over temp. protect, over load protect of blower, dry heat protection |
||||
| Control System | Balanced Temperature & Humidity Control System | ||||
| Refrigeration system | Air Cooled (Water Cooled Type is option) | ||||
| Hermetic compressor,Cascsde Refrigeration, CFC-Free refrigerant(HFC-507/HFC-23) | |||||
| Controller | Panel:7-inch LCD Touch panel, Chinese or English display selectable | ||||
| Operation model :Program or fix point running | |||||
| Memory capacity :120programs,1200steps, | |||||
| All repeat 999 cycles, part repeat 99 cycles | |||||
| Interior material | Stainless Steel Plate ( SUS 304 ) | ||||
| Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | ||||
| Insulation material | Rigid polyurethane Foam and Glass Fiber Wool | ||||
| System | Balanced & Humidity Control System | ||||
| Wiring method | AC 380±10 % 50Hz ,3 phase 4 wires +Ground Wires | ||||
| Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
|||||