Professional Manufacturer 2014 New Style High Low Temperature Climate Chamber
Detailed Picture:
Standard configuration
Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m
No fuse breaker, over pressure,over heat and over current protection for compressor,
Over temperature protection, over load protect of blower, dry heat protection
Optional accessories
Cable Port: Φ100mm cable port is available
Shelves
Ro-type water purifier:R-80/day
Provide to keep the humidifying heater and wet bulb wick free from scale.
Inner glass door with operation port
A glass door can be provided behind the main door so that specimens can be observed. Two operation ports of 130mm diameter are used for handing specimens inside the chamber without opening the glass door.
Dehumidifier
The rotation regenerating dehumidifier M-120 ensures precise control of low humidity (5ºC 5%RH) for electrostatic reliability tests.
Temperature and humidity recorder
-100 to +150ºC/0 to 100%RH 100mm with effective width 100mm and 2 pen
Temperature 1 pen and humidity 1 pen.
-100 to +150ºC/0 to 100%RH 100mm with effective width 100mm and 6 dots
Temperature 3 dots and humidity 1 dot.
-100 to +150ºC/0 to 100%RH 100mm with effective width 180mm and 12 dots
Temperature 6 dots and humidity 6 dots.
Defrosting circuit
The chamber automatically detects and melts the frost on the evaporator when operating below 0ºC.
Liquid or infection
In order to rapidly decrease the temperature inside the chamber, a cylinder of liquid can be connected the chamber.
Parts and their Imported Parts brands: Tecumseh, Danfoss, Bitzer, ESK, ALCO, RANCO, SAGINOMIYA, Castel,
About the LED controller:
Temperature and humidity settings (SV) Actual (PV) value can be displayed directly,
Execution of the program can display numbers, Paragraphs, remaining time and cycles, running time display,
Program editing and graphic curve display,
Fixed or program operation status display,
7-inch TFT display screen.
Technical parameter
Model |
KMH-408L |
408L chamber volume |
Temp. range |
-40°C ~150°C |
Display resolution |
0.1°C |
Temperature stability |
High±0.5°C ,low ±1.0°C |
Temperature uniformity |
±2.0°C |
Heat up time |
-40°C ~+100°C,within 45 min |
Pull down time |
+20°C ~-40°C,within 60 min |
Humidity range |
20~98%R.H,(standard), '10~98%R.H,(with humidifier) |
Humidity constancy |
±2.5%R.H |
Humidity uniformity |
±3.0%R.H |
Interior Dimension(mm) |
700W*750H*800D |
Exterior Dimension(mm) |
980W*1940H*1740D |
Interior material |
Stainless Steel Plate(SUS 304) |
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam and Glass Fiber Wool |
Total power |
7KW(heater 3KW included) |
Max current |
17A |
Water Consumption |
1L/hr |
Ambient Temp. |
+5°C ~+35°C |
Power Supply |
|
AC 380V±10%50Hz ,3 phase 4 wires +Ground Wires |
Weight |
420KG |
Sight window size |
460*560mm |
Sample holder |
2 pcs |
Fittings |
cable port(portΦ50mm)*1, chamber lamp*1, power cable *2m |
Safety device (standard) |
No fuse breaker,over pressure,over heat&over current protect,over temp. protect, over load protect for blower, dry heat protect |
Control System |
Balanced Temperature & Humidity Control (BTHC)System |
Refrigeration system |
Air Cooled (Water Cooled is option) |
Hermetic compressor |
Hermetic compressor Single stage refrigeration system, CFC-Free refrigerant(HFC-507/HFC-23) |
CFC-Free refrigerant(HFC-507/HFC-23) |
Controller |
7-inch LCD Touch Screen panel |
Operation model :Program or fix point running |
Memory capacity :120programs,1200steps, |
All repeat 999 cycles, part repeat 99 cycles |
Note: 1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available |
After-sale service
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.