Application:
Thermal Shock Test Chamber is used to quickly find the hidden mechanical weaknesses in electronic components when test specimens are exposed to rapid thermal shock condition, and you will not only reduce the premature failures but also increase the reliability of your products when you choose our thermal shock test chamber.
About 2-zone thermal shock test chamber:
Defrost: one time / week, about100cycles
Stop testing program to defrost
Automatically defrost without changing the testing temperature
What is temperature compensation?
For example, If your testing temp is -40 ºC, you should set -55ºC. The difference 15 ºC between them is the compensation temperature.
Why?
Because of the heat dissipation
Features
Rational Construction and fast cooling rate
Frequency conversion control of wind speed.
Adopts international brand of imported parts for cooling system to improve operation reliability
Touch screen controller, friendly Man-Machine interface and safety device to ensure simple operation and easy maintenance.
Benifits more than you can get from other supplier
1. Dedicatetouch and excellent user experience
2. Unique and compact design, top grade appearance, stable performance and easy operation
3. Can simulate a wide rang of temperature and humidity environments
4. Capable of testing large components, assemblies, and finished products
5. Customized sizes and configurations available
6. One year warranties
![CE Certificated Raliability 2-Zone Thermal Shock Test Chamber](//www.micstatic.com/athena/img/transparent.png)
![CE Certificated Raliability 2-Zone Thermal Shock Test Chamber](//www.micstatic.com/athena/img/transparent.png)
![CE Certificated Raliability 2-Zone Thermal Shock Test Chamber](//www.micstatic.com/athena/img/transparent.png)
KOMEG, as a professional manufacturer of environmental test chamber for 23 years.
We will attend CISILE 2014 Beijng, Booth No., 1102, on May 21-23, 2014.
Welcome! You will have a new brand concept of our programmable test chambers.
You will find purchasing become easier and more smoothly.
The following is some parts of our company.
SIMENS, EMERSON, Minolta, HUAWEI, TCL, etc. are among our long-term clients.
![CE Certificated Raliability 2-Zone Thermal Shock Test Chamber](//www.micstatic.com/athena/img/transparent.png)
![CE Certificated Raliability 2-Zone Thermal Shock Test Chamber](//www.micstatic.com/athena/img/transparent.png)
Specifications |
Note:1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Model |
KTS-A Series |
KTS-B Series |
KTS-D Series |
72A |
100A |
150A |
200A |
252A |
300A |
480A |
72B |
100B |
150B |
200B |
252B |
300B |
480B |
72D |
100D |
150D |
200D |
252D |
300D |
Interior size |
W(mm) |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
450 |
500 |
600 |
670 |
700 |
800 |
800 |
450 |
500 |
600 |
670 |
700 |
800 |
H(mm) |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
400 |
450 |
500 |
600 |
600 |
600 |
800 |
400 |
450 |
500 |
600 |
600 |
600 |
D(mm) |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
400 |
450 |
500 |
500 |
600 |
650 |
Exterior size |
W(mm) |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
1850 |
1490 |
1540 |
1640 |
1720 |
1750 |
1850 |
H(mm) |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
2200 |
1790 |
1840 |
1890 |
2000 |
2000 |
2000 |
D(mm) |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
2500 |
1600 |
1700 |
1830 |
1850 |
1930 |
1980 |
Test weight(KG) |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
5 |
10 |
12 |
15 |
18 |
20 |
20 |
5 |
10 |
12 |
15 |
18 |
20 |
Low Temp. chamber |
-55ºC~-10ºC |
-70ºC~-10ºC |
-80ºC~-10ºC |
Pre-heat time |
+20ºC~-55ºC ,Within 60 min |
+20ºC~-70ºC ,Within 60 min |
+20ºC~-80ºC ,Within 60 mins |
Test. chamber |
-40ºC~+150ºC |
-55ºC~+150ºC |
-65ºC~+150ºC |
High Temp. chamber |
+60ºC~+200ºC |
Pre-heat time |
+60ºC~+200ºC ,Within 20 min |
Recovery time |
High-Temp Exposure 30 min |
Low-Temp Exposure 30 min |
Recovery time within 5 min |
Safety device |
No fuse breaker, over pressure\over heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection |
Standard accessory |
Cable port(portΦ50mm)*1, shelves*2 |
Interior material |
Stainless steel plate(SUS 304) |
Exterior material |
Baked painting steel or stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam+glass fiber wool |
Refrigeration system |
Water Cooled |
Semi-hermetic compressor, cascade refrigeration system, CFC free refrigerant(HFC-507 and HFC-23) |
Controller |
Panel:7-inch LCD Touch panel,Chinese or English display selectable |
Operation model:Program or fix point running |
Memory capacity:120programs,1200steps,all repeat 999cycles,part repeat 99 cycles. |
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit |
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV |
Ambient Temp. |
+5ºC~+35ºC |
Power |
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |