Customization: | Available |
---|---|
After-sales Service: | 24 Hours on Line Services |
Power Supply: | 380V 50Hz or Customized |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Environmental Temperature and Humidity Testing Chamber | ||||||
Secifications ( at +20°C room temp. Or+25°C water temp with empty load) | ||||||
Model | KMH-L series | |||||
150L | 225L | 408L | 800L | 1000L | ||
Interior sizel | W(mm) | 600 | 700 | 700 | 1000 | 1000 |
H(mm) | 600 | 700 | 750 | 1000 | 1000 | |
D(mm) | 460 | 480 | 800 | 800 | 1000 | |
Exterior size | W(mm) | 880 | 980 | 980 | 1280 | 1280 |
H(mm) | 1730 | 1890 | 1940 | 2160 | 2160 | |
D(mm) | 1400 | 1460 | 1740 | 1750 | 1950 | |
Weight(KG) | 250 | 300 | 420 | 530 | 600 | |
Temp. range | -40 °C ~ +150°C | |||||
Humidity Range | 20 ~ 98&R.H. | |||||
Temp. constancy | ±0.5ºC | |||||
Humidity constancy | ±2.5%R.H | |||||
Humidity uniformity | ±3.0 % R.H | ±5.0 % R.H | ||||
Heat up time | -40°C ~+100°C , within 45 min | |||||
Pull down time | +20°C ~ -40°C , within 60 min | |||||
Equipment Power | 7.5 | 7.5 | 8.5 | 14.5 | 14.5 | |
Ambient Temp. | 5ºC ~+35ºC | |||||
Standard accessories | Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m | |||||
Safety device (standard) | No fuse breaker, over pressure \ over heat and over current protection for compressor, Over temp. protect, over load protect of blower, dry heat protection |
|||||
Control System | Balanced Temperature & Humidity Control System | |||||
Refrigeration system | Air Cooled ( Water Cooled Type is option ) | |||||
Hermetic compressor,Single stage refrigeration system, CFC-Free refrigerant(HFC-507/HFC-23) | ||||||
Controller | Panel:7-inch LCD Touch panel, Chinese or English display selectable | |||||
Operation model :Program or fix point running | ||||||
Memory capacity :120programs,1200steps, | ||||||
All repeat 999 cycles, part repeat 99 cycles | ||||||
Interior material | Stainless Steel Plate ( SUS 304 ) | |||||
Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | |||||
Insulation material | Rigid polyurethane Foam and Glass Fiber Wool | |||||
System | Balanced & Humidity Control System | |||||
Wiring method | AC 380±10 % 50Hz ,3 phase 4 wires +Ground Wires | |||||
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Voltage
|
1Ø 220V 50Hz/ 3Ø 380V 60Hz/Customized
|
Temperature range
|
-70ºC ~180ºC
|
Humidity range
|
10% ~98%RH
(5%~98% R.H. customized) |
Temp.& humidity control fluctuation
|
≤±0.5ºC, ≤ ±2.5%RH
|
Indication resolution
|
0.01ºC, 0.1 %RH
|
Temp.&humidity Uniformity
|
≤±1.5ºC,≤±2.5% RH
|
Heat up&Cool down time
|
≤5ºC/min for heating; ≤ 1.2ºC/min for cooling
|
Cooling type
|
Air cold
|
Chamber materials
|
SUS#304 stainless steel for Inner chamber with thickness 1.5mm
Steel plate for external chamber with thickness 1.5mm |
Insulation materials
|
Rigid polyurethane foam + ultrafine glass fiber with thickness of 100mm
|
|
Refrigerating unit, water supply and drainage device, blower fan, power distributing Cabinet;
Humidifying and humidity measuring water utilization control device |
|
Heat emission blower fan
Distribution switchboard Test terminal of sample USB physical interface (need to be purchased together with centralized monitoring software) Residual current circuit breaker of main power supply |
|
Basin heating humidifying method
Stainless steel armored heater is adopted in basin humidification Control mode of heater: non contact equal period pulse-width modulation, SSR (solid state relay) Water level control device, dry heating prevention device of heater |
Humidifier
|
1.Basin heating humidifying method
2.Control mode of heater: non contact equal period pulse-width modulation, SSR (solid state relay) 3.Water level control device, dry heating prevention device of heater |
|
Temperature (humidity) control display, over temperature protection setting device,emergency switch, run indicator, failure
indicator |
|
Imported Compressor
Fits wide range of pressure Higher heating efficiency Easy to maintain |
|
1.Unique design of the box within the wind circulation structure, to ensure that under the conditions of the test with the case of
uniformity within the box within ± 2 ºC
2.Unique design of the humidity test when the top of the box anti-drip design to ensure that live test from water short circuit,
surface water pollution
3.Using the latest environmentally friendly adsorption drying processor, effective control of the product when the surface
temperature condensation
4.The refrigeration room is fully sealed and soundproofed to reduce machine noise and box resonance, machine noise control within
75db./Other Contact us
|