• Hast Test Machine Semi Conductor Reliability Test Chamber
  • Hast Test Machine Semi Conductor Reliability Test Chamber
  • Hast Test Machine Semi Conductor Reliability Test Chamber
  • Hast Test Machine Semi Conductor Reliability Test Chamber
  • Hast Test Machine Semi Conductor Reliability Test Chamber
  • Hast Test Machine Semi Conductor Reliability Test Chamber

Hast Test Machine Semi Conductor Reliability Test Chamber

After-sales Service: 24 Hours on Line Services
Power Supply: 380V
Certification: CE, ISO
Warranty: 1 Year
Inner Dimension: Diameter 550 mm*D (Depth) 650mm
Outer Dimension: About W900 mm*H1552 mm*D1500 mm
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
R&D Capabilities
The supplier has 21 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (27)

Basic Info.

Model NO.
HAST-55
Device Cooling Method
Natural Cooling or Air Purging Type
Temp. Range
105c~135c(at 100% Relative Humidity)
Humidity Range
Std Saturation Test Mode: 100%Rh
Pressure Range
Gauge Pressure: +0.2 ~ 200kpa
Standards Complied
IEC-60068-2-66
Inside Material
SUS316 Stainless Steel Plate
Transport Package
by Plywood Case
Specification
Ø 550 mm*D650mm
Trademark
KOMEG
Origin
China
HS Code
90321000
Production Capacity
1000PCS/Year

Product Description

PCT High Pressure Accelerated Aging Test Machine Semi conductor reliability Test Chamber

Product description

The PCT high-pressure accelerated aging test is mainly to test moisture resistance of the semiconductor package. The product to be tested is placed in a specific temperature, humidity and pressure environment to test the pressure resistance and air tightness of the sample. If the semiconductor package not good condition, the moisture will follow the glue or the glue and the wire. The interface of the rack penetrates into the package. The common causes of failure include popcorn effect, open circuit caused by corrosion in the metalized area, and short circuit between the pins of the package due to pollution.

Volume and dimension

Volume About 55L
Interior size Ø550 mm*D650mm(Drum type pressure inner box)
  Exterior size W900 mm*H1552mm*D1500 mm(Excluding the protruding part of the machine!)
Tips: For external dimensions, please confirm the three views according to the final design!

The main technical parameters

 Test Conditions Cool method: :Natural cooling or air purging
Measured at a room temperature of +25 ºC under no load, Measured at normal pressure 101.3Kpa, the temperature and humidity performance test is measured according to the relevant regulations according to GB/T 2424.5 or IEC60068 -3; the sensor is placed at the air outlet of the air handling unit.
 Temperature range +105ºC~+135ºC(At 100% relative humidity)
Temp.  fluctuation ±0.5ºC
Temp. uniformity ≤±3.0ºC
Temp. deviation ≤±3.0ºC
  Humidity range 1) HUM unsaturated test mode: 65~100%RH
2) STD saturation test mode: 100%RH
 Humidity Fluctuation ±3.0%RH
 Humidity Deviation ±5.0%RH
 Temperature change rate Heat up rate:
 +25ºC~+135ºC, full range average speed  approx 45 min (no-load,no heating)
Load no
  Note:Measured at a room temperature of +25 ºC under no load,the temperature and humidity performance test is measured according to the relevant regulations according to GB/T 2424.5 or IEC60068 -3; the sensor is placed at the air outlet of the air handling unit.
  Pressure range Gauge pressure: +0.2 ~ 200Kpa
*Absolute pressure: 100 ~ 300Kpa
  Pressure deviation ≤±2 kPa
  Pressure rise time Atmospheric pressure to 200Kpa   20min


Product technical features

·Using wet and dry bulb sensor for direct measurement

The control modes are divided into three modes: dry and wet bulb, unsaturated and wet saturated.

·Double-layer cylinder structure, multiple protection functions

The inner tank adopts a circular arc design to prevent condensation and dripping water, which meets the national safety container regulations. Multiple man-machine protections such as various over-pressure and over-temperature, dry-burning leakage and misoperation.

·Slow pressure reduction treatment, optional exhaust and drainage mode

Prevent the sample from being affected by sudden pressure, temperature or water evaporation after the test.

·Automatic water replenishment function, front water level confirmation

At the beginning of the test, the system will automatically add enough water for the test at one time, and the remaining water in the tank can be simply confirmed from the front.

·Komeg independently researched and developed control system, intelligent setting, easy operation

It adopts 7-inch true color touch screen, has 250 groups of 12,500 programs, has USB curve data download function, and RS-485 communication interface.
Hast Test Machine Semi Conductor Reliability Test Chamber
Hast Test Machine Semi Conductor Reliability Test ChamberHast Test Machine Semi Conductor Reliability Test ChamberHast Test Machine Semi Conductor Reliability Test ChamberHast Test Machine Semi Conductor Reliability Test Chamber


PCT high pressure accelerated aging test conditions

Test equipment: KOMEG brand PCT pressure cooker testing chamber

Temperature range: +105ºC to +162.5ºC, humidity range: 100%R.H

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now