Reliability Temperature Humidity Test Chamber for airplanes or helicopters
Application
Temperature and Humidity Test Chamber is able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability.
The technical parameter is as the following:
Environmental Temperature and Humidity Chamber |
|
Secifications ( at +20ºC room temp. Or+25ºC water temp with empty load) |
Model |
KMH-R series |
KMH-L series |
KMH-S series |
150R |
225R |
408R |
800R |
1000R |
150L |
225L |
408L |
800L |
1000L |
225S |
408S |
800S |
1000S |
Temp. range |
-20ºC~150ºC |
-40 ºC~+150ºC |
-70ºC~+150ºC |
Interior sizel |
W(mm) |
600 |
700 |
700 |
1000 |
1000 |
600 |
700 |
700 |
1000 |
1000 |
700 |
700 |
1000 |
1000 |
H(mm) |
600 |
700 |
750 |
1000 |
1000 |
600 |
700 |
750 |
1000 |
1000 |
700 |
750 |
1000 |
1000 |
D(mm) |
460 |
480 |
800 |
800 |
1000 |
460 |
480 |
800 |
800 |
1000 |
480 |
800 |
800 |
1000 |
Exterior size |
W(mm) |
880 |
980 |
980 |
1280 |
1280 |
880 |
980 |
980 |
1280 |
1280 |
980 |
980 |
1280 |
1280 |
H(mm) |
1730 |
1890 |
1940 |
2160 |
2160 |
1730 |
1890 |
1940 |
2160 |
2160 |
1890 |
1940 |
2160 |
2160 |
D(mm) |
1400 |
1460 |
1740 |
1750 |
1950 |
1400 |
1460 |
1740 |
1750 |
1950 |
1460 |
1740 |
1750 |
1950 |
Power(KW) |
5.8 |
6 |
7.5 |
12.8 |
12.8 |
7.5 |
7.5 |
8.5 |
14.5 |
14.5 |
9.5 |
10.6 |
18.5 |
18.5 |
Weight(KG) |
240 |
280 |
400 |
500 |
580 |
250 |
300 |
420 |
530 |
600 |
330 |
450 |
550 |
650 |
Humidity uniformity |
±3.0%R.H |
±5.0%R.H |
±3.0%R.H |
±5.0%R.H |
±3.0%R.H |
±5.0%R.H |
Heat up time |
-20ºC~+100ºC,within 35 min |
-40ºC~+100ºC, within 45 min |
-70ºC~+100ºC,within 60 min |
Pull down time |
+20ºC~-20ºC, within 45 min |
+20ºC~-40ºC , within 60 min |
+20ºC~-70ºC,within 80 min |
Standard accessories |
Sight window*1, cable port(portΦ50mm)*1, shelves*2, chamber lamp*1, power cable *2m |
Safety device (standard) |
No fuse breaker, over pressure\over heat and over current protection for compressor,
Over temp. protect, over load protect of blower, dry heat protection |
Control System |
Balanced Temperature & Humidity Control System |
Refrigeration system |
Air Cooled (Water Cooled Type is option) |
Hermetic compressor,Single stage refrigeration system, CFC-Free refrigerant(HFC-507/HFC-23) |
Hermetic compressor, Cascade Refrigeration , CFC free refrigerant (HFC-507/HFC-23) |
Controller |
Panel:7-inch LCD Touch panel, Chinese or English display selectable |
Operation model :Program or fix point running |
Memory capacity :120programs,1200steps, |
All repeat 999 cycles, part repeat 99 cycles |
Humidity Range |
20~98%R.H |
Temp. constancy |
±0.5ºC |
Humidity constancy |
±2.5%R.H |
Temp. uniformity |
±2.0ºC |
Interior material |
Stainless Steel Plate(SUS 304) |
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
Insulation material |
Rigid polyurethane Foam and Glass Fiber Wool |
Ambient Temp. |
+5ºC~+35ºC |
Wiring method |
|
AC 380±10%50Hz ,3 phase 4 wires +Ground Wires |
Note:
1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available |
Standard configurations:
Sight window X 1
Cable port (port Ø 50mm) X 1
Shelves X 2
Chamber lamp X 1
Power cable X 2m
No fuse breaker, over-pressure, over-heat and over-current for compressor, over-temperature, overloading of blower, dry heat-protection
Optional accessories:
Cable port: Ø 100mm is available
Shelves
RO-type water purifier: R-80/day
Provided to keep the humidifying heater and wet bulb wick free from scale
Inner glass door with operating port: A glass door can be provided behind the main door so that specimens can be observed
Two operating ports of 130mm diameter are used for handing specimens inside the chamber without opening the glass door
Dehumidifier: The rotation regenerating dehumidifier M-120 ensures precise control of low-humidity (5° C 5% RH) for electronics