Customization: | Available |
---|---|
Power Supply: | 380V /220V |
Certification: | CE, ISO |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High-Temperature Uniformity 408L Environmental Test Chamber for Electronics 85%R.H 85ºC Testing
1. Application:
Temperature humidity chambers doing 85%R.H. at 85C testing. You can see the new design and testing performance.
2. Features:
The new general design improved several parts:
water and electrical system separate design, outside humidifying, so the electronics components have long service life; the controller is located on the left part of the door, space-saving, much convenient for operation. the electrical control panel is located on the left.
3. Temperature Humidity Test Chamber Features:
a. High-quality appearance, the body adopted an arc shape, surface automobile coating technology processing, and mechanical explosion-proof handle, easy to operate, safe, and reliable.
b. Rectangular multi-layer glass View window, the use of guinea pigs observed in the test window with anti-sweat heaters device prevents water gas condensate, knot, water droplets, LED lamps to keep the inside lighting.
c. The door frame with airtight packing can be effectively isolated from the internal temperature of the leak
d. With an external water supply system, convenient to supplement the cylinder water supply, and automatic recovery using.
e. Compressor cycling system used France "Tecumseh" brand which can effectively remove condenser pipe and between capillary Lubricating oil and whole series adopt environmental protection refrigerant (R23, R404, R507)
f. The controller uses the imported LCD display screen, can display measured values (PV) and setting values (SV) time
Temp. Cycle Compare |
High Temp. High Humidity |
Low Temp |
Temp. Change Rate |
Cycle No. |
IEC61215 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
GB9535 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
IEC61646 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
GB18911 |
85ºC/85±5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
UL1703 |
85ºC/85±2.5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
10 |
IEC62108 |
85ºC/85±2.5%(20h) |
-40ºC(0.5~4h) |
High Temp. Rise& Fall(100ºC/h) |
20 |
3). Thermal cycle test;
Test requirements: -40ºC lowest temperature and 85ºC highest temperature
Temperature falling/rising speed rate:100ºC/Hour=1.67ºC/min,6 hours per cycle,
Test Duration: 50~200 cycles
total testing time last 300 to 1200 hours (12.5 to 50 days)
Temp. Cycle Compare |
Low Temp |
High Temp |
Temp Change RateºC/h |
Dwell Time |
Cycle Number. |
IEC61215 |
-40±2ºC |
85±2ºC |
Max. 100ºC/h |
Min.10min |
50, 200 |
GB9535 |
-40±2ºC |
85±2ºC |
Max.100ºC/h |
Min.10min |
50, 200 |
IEC61646 |
-40±2ºC |
85±2ºC |
Max.100ºC/h |
Min.10min |
50, 200 |
GB18911 |
-40±2ºC |
85±2ºC |
Max.100ºC/h |
Min.10min |
50, 200 |
UL1703 |
-40±2ºC |
90±2ºC |
Max.120ºC/h |
30~105min |
200 |
IEC62108 |
-40±2ºC |
65ºC,85ºC,110ºC |
10cycle/day |
10min |
500,1000,2000 |
IEC62108 |
-40ºC |
65ºC,85ºC,110ºC |
18cycle/day |
10min |
500,1000,2000 |
IEEE1513 |
-40ºC |
90ºC,110ºC |
0.9~7.5ºC/min |
Min.10min |
250,500 |
IEEE1513 |
-40ºC |
90ºC,110ºC |
Max.100ºC/h |
Min.10min |
100,200 |
IEEE1513 |
-40ºC |
60ºC,90ºC |
Max.100ºC/h |
Min.10min |
50,200 |
4. Temperature Humidity Test Chamber Technical Specifications
Model | KMH-408R | KMH-408L | KMH-408S |
408L chamber volume | |||
Temp. range | -20°C ~150°C | -40°C ~150°C | -70°C ~150°C |
Display resolution | 0.1°C | ||
Temperature stability | High±0.5°C, low ±1.0°C | ||
Temperature uniformity | ±2.0°C | ||
Heat uptime | -20°C ~+100°C, within 35 min | ' -40°C ~+100°C, within 45 min | ' -70°C ~+100°C, within 60 min |
Pull downtime | -20°C ~-20°C, within 45 min | ' +20°C ~-40°C, within 60 min | ' +20°C ~-70°C, within 80 min |
Humidity range | 20~98%R.H,(standard), '10~98%R.H,(with humidifier) | ||
Humidity constancy | ±2.5%R.H | ||
Humidity uniformity | ±3.0%R.H | ||
Interior Dimension(mm) | 700W*750H*800D | ||
Exterior Dimension(mm) | 980W*1940H*1740D | ||
Interior material | Stainless Steel Plate(SUS 304) | ||
Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | ||
Insulation material | Rigid polyurethane Foam and Glass Fiber Wool | ||
Total power | 6KW(heater 3KW included) | '7KW(heater 3KW included) | '9KW(heater 3KW included) |
Max current | 17A | 17A | 19A |
Water Consumption | 1L/hr | 1L/hr | 1L/hr |
Ambient Temp. | +5°C ~+35°C | ||
Power Supply | AC 380V±10% 50Hz,3 phase 4 wires +Ground Wires | ||
Weight | 400KG | 420KG | 450KG |
Sight window size | 460*560mm | ||
Sample holder | 2 pcs | ||
Fittings | cable port(portΦ50mm)*1, chamber lamp*1, power cable *2m | ||
Safety device (standard) | No fuse breaker(NFB), overpressure, overheat & over-current protect, over temp. protect, overload protect for the blower, dry heat protect | ||
Control System | Balanced Temperature & Humidity Control (BTHC)System | ||
Refrigeration system | Air Cooled (Water Cooled is an option) | ||
Hermetic compressor | |||
Hermetic compressor Single stage refrigeration system, CFC-Free refrigerant(HFC-507/HFC-23) | |||
CFC-Free refrigerant(HFC-507/HFC-23) | |||
Controller | 7-inch LCD Touch Screen panel | ||
Operation model: Program or fixpoint running | |||
Memory capacity :120programs,1200steps, | |||
All repeat 999 cycles, part repeat 99 cycles | |||
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
6. Package:
PP film first, and then 10mm foam between machine and the case, and outside is standard export plywood case.
7. Application
An environmental test chamber artificially replicates the conditions under which machinery, materials, devices, or components might be exposed. It is also used to accelerate the effects of exposure to the environment, sometimes at conditions not actually expected.